Showing all 4 results

DCP 1200 1.2KVA

LKR32,500.00
  • 1200VA /720W
  • Intelligent CPU Controlled
  • Wide input range (220V ± 25%)
  • Fully AVR
  • Cold start Available
  • Strong generator compatibility
  • 2 YEARS WARRANTY(BATTERY 1 YEAR)

DCP 650VA

LKR12,500.00

(W) 390W

Input Voltage (V) 160+10%

Output Frequency (Hz) 50Hz+10%

Transfer Time (ms) <6ms

Voltage AVR Mode 230V AC Nominal

Output Waveform Quasi Sine Wave (Battery) Sine Wave (Mains) Battery Type Sealed Lead Acid Maintenance Free

Recharge Time 90% Capacity After 5Hours

Backup 7-15 min ( depending on the connected Load)

General Protection Under Voltage, Over Voltage, Spikes, Surge Su

Energy 320 Joules Instantaneous Respon

Test Standard IEEE587 Cat A&B

Noice Filtering EMI/EFI Full time Suppression

Communication Interface USB

Telephone Line RJ11

Output Sockets Universal Sockets

Panel Display Mains On, Mains Full, Battery Low

Noice <0 - 45 db (1Miter)

Temperature 0~40C

Hamidity 20~90% (Non - Condensing)

Dimension (L/xWxH),, 287 x 100 x 145

Weight (Kg) 5

2 YEARS WARRANTY(1 YEAR BATTERY)

PROLINK PRO1201SFC 1200VA

LKR29,500.00
Capacity 1200VA Input Voltage Range 220 - 240V ± 5% Frequency 50Hz/60Hz (Auto-sensing) Phase Single + GND Output Voltage Range 230VAC +12% -14% Battery Mode 230VAC +10% -10% Frequency 50Hz ± 1% (Battery Mode) Waveform - Simulated Sine Wave (Battery Mode) - Sine Wave (AC Mode) Transfer Time 2ms typical Battery Type 12V/8.2AH - 2pcs Backup Time 8 - 30 minutes depending on load Recharge Time 2 - 4 hours recover to 90% capacity Protection / Monitoring Short Circuit Protection Yes (Line Mode and Battery Mode) Surge Protection Yes Alarm Audible & Visual UPS Protection Load auto sensing and abnormal protection Overload Protection - Line mode : 100 - 120% 5 mins change to fault mode >120% change to fault mode shutdown immediately - Battery mode : 100 - 110% alarm & shutdown in 10 secs >120% shutdown immediately Intelligent Battery Management Prevent overcharging of battery Protect battery and prolong battery life Interface Interface* RJ11 AC fault, battery low, shutdown UPS General Software Support Windows® 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix, and Mac Noise Level <40dB Temperature 0°C - 40°C Humidity 0 - 90% Power Factor Up to 0.7 Built in AVR TRUE Full AVR (3 steps) Physical Dimension (mm) D x W × H 320*130*182mm (product only) 390*192*275mm (with box) Net Weight (kgs) 8.6KG (product only) 9KG(with box) Package Content 1 x PROLiNK PRO1200SFC 1 x Quick Installation Guide (QIG) 2 YEARS WARRANTY(BATTERY 1 YEAR)

PROLINK PRO701SFC 650VA

LKR14,500.00
Capacity : 650VA Input Voltage Range: 140-300VAC Output Frequency : 50Hz or 60Hz ±1Hz Number Of Batteries : 1 x 12V8.2AH Recharge Time (Typical) : 2 – 4 hours recover to 90% capacity Protection : Short Circuit, Overload, Discharge and Overcharge Protection Indication : LED Display Dimensions (mm) D x W × H : 324 x 220 x 140 mm Net Weight (kgs) : 4.25 WARRANTY 2 YEARS(BATTERY 1 YEAR)